Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 138
Filtrar
1.
Catheter Cardiovasc Interv ; 103(6): 1004-1014, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38577939

RESUMO

INTRODUCTION: Bicuspid aortic valve (BAV) stenosis is a complex anatomical scenario for transcatheter aortic valve implantation (TAVI). Favorable short-term clinical outcomes have been reported with TAVI in this setting, but long-term data are scarce. METHODS: We retrospectively included, in a single-center registry, patients with BAV stenosis who underwent TAVI before 2020. We compared patients treated with self-expanding valves (SEV) versus balloon-expandable valves (BEV). The primary endpoint was a composite of all-cause mortality, stroke and need for aortic valve (AV) reintervention at 3 years. Secondary endpoints included each component of the primary endpoint, cardiovascular mortality, permanent pacemaker implantation (PPI) rate, mean gradient and ≥moderate paravalvular leak (PVL) rate. RESULTS: A total of 150 consecutive patients (SEV = 83, BEV = 67) were included. No significant differences were reported between SEV and BEV groups for the primary composite endpoint (SEV 35.9% vs. BEV 32%, p = 0.66), neither for clinical secondary endpoints (all-cause mortality SEV 28.1% vs. BEV 28%, p = 0.988; cardiovascular mortality SEV 14.1% vs. BEV 20%, p = 0.399; stroke SEV 12.5% vs. BEV 6%, p = 0.342; need for AV reintervention SEV 0% vs. BEV 0%; PPI SEV 28.1% vs. BEV 24%, p = 0.620). A lower mean gradient persisted up to 3 years in the SEV group (SEV 8.8 ± 3.8 mmHg vs. BEV 10.7 ± 3.2 mmHg, p = 0.063), while no significant difference was found in the rate of ≥ moderate PVL (SEV 3/30 vs. BEV 0/25, p = 0.242). CONCLUSIONS: In this single center registry, we observed favorable 3-year clinical outcomes in nonselected BAV patients treated with different generation devices, without significant differences between patients receiving SEV or BEV.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Doença da Válvula Aórtica Bicúspide , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Masculino , Feminino , Estudos Retrospectivos , Resultado do Tratamento , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Fatores de Tempo , Idoso , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Idoso de 80 Anos ou mais , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/anormalidades , Recuperação de Função Fisiológica , Hemodinâmica , Medição de Risco
2.
JACC Cardiovasc Interv ; 17(5): 648-661, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38385922

RESUMO

BACKGROUND: Early studies of the Tendyne transcatheter mitral valve replacement (TMVR) showed promising results in a small selective cohort. OBJECTIVES: The authors present 1-year data from the currently largest commercial, real-world cohort originating from the investigator-initiated TENDER (Tendyne European Experience) registry. METHODS: All patients from the TENDER registry eligible for 1-year follow-up were included. The primary safety endpoint was 1-year cardiovascular mortality. Primary performance endpoint was reduction of mitral regurgitation (MR) up to 1 year. RESULTS: Among 195 eligible patients undergoing TMVR (median age 77 years [Q1-Q3: 71-81 years], 60% men, median Society of Thoracic Surgeons Predicted Risk of Mortality 5.6% [Q1-Q3: 3.6%-8.9%], 81% in NYHA functional class III or IV, 94% with MR 3+/4+), 31% had "real-world" indications for TMVR (severe mitral annular calcification, prior mitral valve treatment, or others) outside of the instructions for use. The technical success rate was 95%. The cardiovascular mortality rate was 7% at 30 day and 17% at 1 year (all-cause mortality rates were 9% and 29%, respectively). Reintervention or surgery following discharge was 4%, while rates of heart failure hospitalization reduced from 68% in the preceding year to 25% during 1-year follow-up. Durable MR reduction to ≤1+ was achieved in 98% of patients, and at 1 year, 83% were in NYHA functional class I or II. There was no difference in survival and major adverse events between on-label use and "real-world" indications up to 1 year. CONCLUSIONS: This large, real-world, observational registry reports high technical success, durable and complete MR elimination, significant clinical benefits, and a 1-year cardiovascular mortality rate of 17% after Tendyne TMVR. Outcomes were comparable between on-label use and "real-world" indications, offering a safe and efficacious treatment option for patients without alternative treatments. (Tendyne European Experience Registry [TENDER]; NCT04898335).


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Masculino , Humanos , Idoso , Feminino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco/métodos , Sistema de Registros
3.
JACC Cardiovasc Interv ; 17(4): 552-560, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38418058

RESUMO

BACKGROUND: Transcatheter tricuspid valve replacement (TTVR) abolishes tricuspid regurgitation (TR) and has emerged as a definitive treatment for TR. OBJECTIVES: The purpose of this multicenter, observational study was to determine the clinical characteristics and short-term outcomes of patients with TR screened for TTVR. METHODS: Patients underwent TTVR screening at 7 centers on a compassionate-use basis. The primary endpoints were NYHA functional class and TR grade at 30-day follow-up. Secondary endpoints included all-cause mortality, heart failure hospitalization, technical success, and reasons for TTVR screening failure. RESULTS: A total of 149 patients (median age 79 years [Q1-Q3: 72-84 years], 54% women) underwent TTVR screening. The TTVR screening failure rate was 74%, mainly related to large tricuspid annular diameter. Patients undergoing TTVR (n = 38) had significant functional improvements (NYHA functional class I or II from 21% to 68%; P < 0.001), with TR ≤1+ in 97% at 30-day follow-up (P < 0.001 from baseline). Technical success was achieved in 91%, with no intraprocedural mortality or conversion to surgery. At 30-day follow-up, mortality was 8%, heart failure hospitalization 5%, major bleeding 18%, and reintervention 9%. Patients who failed screening for TTVR and subsequently underwent "bailout" transcatheter edge-to-edge repair (n = 26) had favorable outcomes (NYHA functional class I or II from 27% to 58%; P < 0.001), with TR ≤1+ in 43% at 30-day follow-up (P < 0.001 from baseline). CONCLUSIONS: This first real-world report of TTVR screening demonstrated a high screening failure rate, mainly related to large tricuspid annular diameter. Patients undergoing TTVR had superior TR reduction and symptom alleviation compared with bailout tricuspid transcatheter edge-to-edge repair, at the cost of greater procedural complications.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso , Masculino , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Recuperação de Função Fisiológica , Fatores de Tempo , Índice de Gravidade de Doença , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Sistema de Registros
4.
Arch Cardiovasc Dis ; 117(3): 213-223, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38388290

RESUMO

BACKGROUND: The influence of permanent pacemaker implantation upon outcomes after transcatheter aortic valve implantation (TAVI) remains controversial. AIMS: To evaluate the impact of permanent pacemaker implantation after TAVI on short- and long-term mortality, and on the risk of hospitalization for heart failure. METHODS: Data from the large FRANCE-TAVI registry, linked to the French national health single-payer claims database, were analysed to compare 30-day and long-term mortality rates and hospitalization for heart failure rates among patients with versus without permanent pacemaker implantation after TAVI. Multivariable regressions were performed to adjust for confounders. RESULTS: A total of 36,549 patients (mean age 82.6years; 51.6% female) who underwent TAVI from 2013 to 2019 were included in the present analysis. Among them, 6999 (19.1%) received permanent pacemaker implantation during the index hospitalization, whereas 232 (0.6%) underwent permanent pacemaker implantation between hospital discharge and 30days after TAVI, at a median of 11 (interquartile range: 7-18) days. In-hospital permanent pacemaker implantation was not associated with an increased risk of death between discharge and 30days (adjusted odds ratio: 0.91, 95% confidence interval: 0.64-1.29). At 5years, the incidence of all-cause death was higher among patients with versus without permanent pacemaker implantation within 30days of the procedure (adjusted hazard ratio: 1.13, 95% confidence interval: 1.07-1.19). Permanent pacemaker implantation within 30days of TAVI was also associated with a higher 5-year rate of hospitalization for heart failure (adjusted subhazard ratio: 1.17, 95% confidence interval: 1.11-1.23). CONCLUSIONS: Permanent pacemaker implantation after TAVI is associated with an increased risk of long-term hospitalization for heart failure and all-cause mortality. Further research to mitigate the risk of postprocedural permanent pacemaker implantation is needed as TAVI indications expand to lower-risk patients.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Resultado do Tratamento , Sistema de Registros , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Valva Aórtica/cirurgia
5.
Eur Heart J ; 45(11): 940-949, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38243821

RESUMO

BACKGROUND AND AIMS: Mitral valve surgery and, more recently, mitral transcatheter edge-to-edge repair (TEER) are the two treatments of severe mitral regurgitation in eligible patients. Clinical comparison of both therapies remains limited by the number of patients analysed. The objective of this study was to analyse the outcomes of mitral TEER vs. isolated mitral valve surgery at a nationwide level in France. METHODS: Based on the French administrative hospital discharge database, the study collected information for all consecutive patients treated for mitral regurgitation with isolated TEER or isolated mitral valve surgery between 2012 and 2022. Propensity score matching was used for the analysis of outcomes. RESULTS: A total of 57 030 patients were found in the database. After matching on baseline characteristics, 2160 patients were analysed in each arm. At 3-year follow-up, TEER was associated with significantly lower incidence of cardiovascular death (hazard ratio 0.685, 95% confidence interval 0.563-0.832; P = .0001), pacemaker implantation, and stroke. Non-cardiovascular death (hazard ratio 1.562, 95% confidence interval 1.238-1.971; P = .0002), recurrent pulmonary oedema, and cardiac arrest were more frequent after TEER. No significant differences between the two groups were observed regarding all-cause death (hazard ratio 0.967, 95% confidence interval 0.835-1.118; P = .65), endocarditis, major bleeding, atrial fibrillation, and myocardial infarction. CONCLUSIONS: Our results suggest that TEER for severe mitral regurgitation was associated with lower cardiovascular mortality than mitral surgery at long-term follow-up. Pacemaker implantation and stroke were less frequently observed after TEER.


Assuntos
Fibrilação Atrial , Endocardite , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Acidente Vascular Cerebral , Humanos , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Acidente Vascular Cerebral/epidemiologia , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Bases de Dados Factuais , Resultado do Tratamento
6.
Artigo em Inglês | MEDLINE | ID: mdl-38135568

RESUMO

BACKGROUND: Vascular complications (VCs) still represent one of the principal concerns of trans-femoral trans-catheter aortic valve replacement (TF-TAVR). New-generation devices can minimize such complications but the arterial access management is left to the operator's choice. This study aims to describe the rate of VCs in a contemporary cohort of patients undergoing TAVR with new-generation devices and to determine whether an ultrasound-guided (USG) vs. a fluoroscopy-guided (FG) femoral access management has an impact on their prevention. METHODS: This is a prospective, observational, multicenter study. Consecutive patients undergoing TAVR with new-generation devices were analyzed from January 2022 to October 2022 in five tertiary care centers. Femoral accesses were managed according to the operator's preferences. All the patients underwent a pre-discharge peripheral ultrasound control. VCs and bleedings were the main endpoints of interest. RESULTS: A total of 458 consecutive patients were enrolled (274 in the USG group and 184 in the FG group). VCs occurred in 6.5 % of the patients (5.2 % minor and 1.3 % major). There was no difference between the USG and the FG groups in terms of any VCs (7.3 % vs. 5.4 %; p = 0.4), or any VARC-3 bleedings (6.9 % vs 6 %, p = 0.9). At logistic regression analysis, the two guidance strategies did not result as predictors of VCs (odds Ratio 0.8, 95 % Confidence Interval 0.46-1.4; P = 0.4). CONCLUSIONS: In a contemporary cohort of patients undergoing TAVR with new-generation devices, the occurrence of VCs is low and mostly represented by minor VCs. USG and FG modalities did not affect the rate of VCs.

7.
JACC Cardiovasc Interv ; 16(24): 2951-2962, 2023 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-38151309

RESUMO

BACKGROUND: Bleeding is one of the most frequent complications in patients undergoing transcatheter aortic valve replacement (TAVR). Importantly, major bleeding is associated with poor clinical outcomes after TAVR. However, large studies on bleeding complications in the contemporary TAVR population are limited. OBJECTIVES: The aim of this study was to assess the incidence, temporal trends, clinical outcomes, and predictors of bleeding in patients undergoing transfemoral TAVR. METHODS: The CENTER2 study is a pooled patient-level database from 10 clinical studies including patients who underwent TAVR between 2007 and 2022. RESULTS: A total of 23,562 patients underwent transfemoral TAVR. The mean age was 81.5 ± 6.7 years, and 56% were women. Major bleeding within the first 30 days was observed in 1,545 patients (6.6%). Minor bleeding was reported in 1,143 patients (4.7%). Rates of major bleeding decreased from 11.5% in 2007-2010 to 5.5% in 2019-2022 (Ptrend < 0.001). Dual antiplatelet therapy was associated with higher major bleeding rates compared with single antiplatelet therapy (12.2% vs 9.1%; OR: 1.40; 95% CI: 1.13-1.72; P = 0.002). Patients with major bleeding had increased mortality risk during the first 30 days (14.1% vs 4.3%; OR: 3.66; 95% CI: 3.11-4.31; P < 0.001) and during 1-year follow-up (27.8% vs 14.5%; HR: 1.50; 95% CI: 1.41-1.59; P < 0.001). Minor bleeding did not affect 1-year mortality risk (16.7% vs 14.5%; HR: 1.11; 95% CI: 0.93-1.32; P = 0.27). Predictors of major bleeding were female sex and peripheral vascular disease. CONCLUSIONS: Bleeding complications remain frequent and important in patients undergoing transfemoral TAVR. Increased mortality risk in major bleeding persists after the initial 30 days. (Cerebrovascular Events in Patients Undergoing Transcatheter Aortic Valve Implantation With Balloon-Expandable Valves Versus Self-Expandable Valves [CENTER]; NCT03588247).


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Incidência , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Hemorragia/epidemiologia , Hemorragia/etiologia , Fatores de Risco
9.
J Clin Med ; 12(22)2023 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-38002687

RESUMO

Bicuspid aortic valve (BAV) is the most common congenital heart disease, with a prevalence of 1-2% and occurring in >20% of octogenarians referred for aortic valve replacement. However, BAV patients have been systematically excluded from pivotal randomized trials. Since TAVI indications are moving toward low-risk patients, an increase in the number of BAV patients who undergo TAVI is expected. BAV represents a challenge due to its unique morphological features (raphe, extreme asymmetrical valve calcifications, cusp asymmetry and aortopathy) and the lack of consensus about the accurate sizing method. The role of multi-slice computed tomography (MSCT) in the planification of the TAVI procedure is well-established, being useful to define the optimal valve sizing and the implantation strategy. New-generation devices, more experience of the operators and better planification of the procedure have been associated with similar clinical outcomes in bicuspid and tricuspid patients undergoing TAVI.

10.
Eur Heart J ; 44(46): 4862-4873, 2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-37930776

RESUMO

BACKGROUND AND AIMS: For patients with symptomatic, severe tricuspid regurgitation (TR), early results of transcatheter tricuspid valve (TV) intervention studies have shown significant improvements in functional status and quality of life associated with right-heart reverse remodelling. Longer-term follow-up is needed to confirm sustained improvements in these outcomes. METHODS: The prospective, single-arm, multicentre TRISCEND study enrolled 176 patients to evaluate the safety and performance of transcatheter TV replacement in patients with ≥moderate, symptomatic TR despite medical therapy. Major adverse events, reduction in TR grade and haemodynamic outcomes by echocardiography, and clinical, functional, and quality-of-life parameters are reported to one year. RESULTS: Enrolled patients were 71.0% female, mean age 78.7 years, 88.0% ≥ severe TR, and 75.4% New York Heart Association classes III-IV. Tricuspid regurgitation was reduced to ≤mild in 97.6% (P < .001), with increases in stroke volume (10.5 ± 16.8 mL, P < .001) and cardiac output (0.6 ± 1.2 L/min, P < .001). New York Heart Association class I or II was achieved in 93.3% (P < .001), Kansas City Cardiomyopathy Questionnaire score increased by 25.7 points (P < .001), and six-minute walk distance increased by 56.2 m (P < .001). All-cause mortality was 9.1%, and 10.2% of patients were hospitalized for heart failure. CONCLUSIONS: In an elderly, highly comorbid population with ≥moderate TR, patients receiving transfemoral EVOQUE transcatheter TV replacement had sustained TR reduction, significant increases in stroke volume and cardiac output, and high survival and low hospitalization rates with improved clinical, functional, and quality-of-life outcomes to one year. Funded by Edwards Lifesciences, TRISCEND ClinicalTrials.gov number, NCT04221490.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso , Masculino , Insuficiência da Valva Tricúspide/epidemiologia , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Índice de Gravidade de Doença
11.
Can J Cardiol ; 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37923124

RESUMO

BACKGROUND: The risks of prefrail and frail women undergoing transcatheter aortic valve replacement (TAVR) have not been fully examined. The aim of the analysis was to assess the prognostic impact of prefrailty and frailty in women undergoing TAVR. METHODS: Women at intermediate or high surgical risk with severe aortic stenosis undergoing TAVR from the prospective multicentre WIN-TAVI (Women's International Transcatheter Aortic Valve Implantation) registry were stratified based on the number of Fried frailty criteria (weight loss, exhaustion, low physical activity, slow gait, weakness) met: nonfrail (no criteria), prefrail (1 or 2 criteria), or frail (3 or more criteria). The primary outcome at 1 year was the Valve Academic Research Consortium 2 (VARC-2) efficacy end point, a composite of mortality, stroke, myocardial infarction, hospitalisation for valve-related symptoms or heart failure, and valve-related dysfunction; secondary outcomes included the composite of VARC-2 life-threatening or major bleeding. RESULTS: Out of 1019 women, 297 (29.1%) met at least 1 frailty criterion: 264 (25.9%) had prefrailty and 33 (3.2%) frailty. The 1-year risk of the primary outcome was significantly higher in prefrail and frail (20.2%) than in nonfrail (14.9%) women (adjusted hazard ratio [aHR] 1.51, 95% confidence interval [CI] 1.07-2.12). The risk of VARC-2 life-threatening or major bleeding was higher in prefrail or frail (19.9%) than in nonfrail (10.0%) women (aHR 2.06, 95% CI 1.42-2.97). These risks were consistently increased in the prefrail and frail groups assessed separately. CONCLUSIONS: In women undergoing TAVR, the presence of prefrailty or frailty conferred an increased risk of the VARC-2 efficacy end point and of VARC-2 life-threatening or major bleeding.

12.
Ann Thorac Surg ; 2023 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-37717882

RESUMO

BACKGROUND: Whether transcatheter mitral valve replacement (TMVR) devices perform similarly with respect to the underlying mitral regurgitation (MR) etiology remains unknown. The aim of the present analysis was to assess outcomes of TMVR according to the MR underlying etiology among the CHoice of OptImal transCatheter trEatment for Mitral Insufficiency (CHOICE-MI) registry. METHODS: Of 746 patients, 229 patients (30.7%) underwent TMVR. The study population was subdivided according to primary, secondary, or mixed MR. Patients with mitral annular calcification were excluded. The primary study endpoint was a composite endpoint of all-cause mortality or hospitalization for heart failure at 1 year. Secondary study endpoints were all-cause and cardiovascular mortality at 1 year, New York Heart Association functional class, and residual MR, both at discharge and 1 year. RESULTS: The predominant MR etiology was secondary MR (58.4%), followed by primary MR (28.7%) and mixed MR (12.9%). Technical success and procedural mortality were similar according to MR etiology. Discharge echocardiography revealed residual MR 2+ in 11.3%, 3.7%, and 5.3% of patients with primary, secondary, and mixed MR, respectively (P = .1). MR elimination was similar in all groups up to the 1-year follow-up. There was no difference in terms of primary combined outcome occurrence according to MR etiology. One-year all-cause mortality was reported in 28.8%, 24.2%, and 32.1% of patients with primary, secondary, and mixed MR, respectively (P = .07). CONCLUSIONS: In our study we did not find differences in short-term and 1-year outcomes after TMVR according to MR etiology.

13.
EuroIntervention ; 19(8): 634-651, 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37624587

RESUMO

Valvular heart disease (VHD) is one of the most frequent causes of heart failure (HF) and is associated with poor prognosis, particularly among patients with conservative management. The development and improvement of catheter-based VHD interventions have broadened the indications for transcatheter valve interventions from inoperable/high-risk patients to younger/lower-risk patients. Cardiogenic shock (CS) associated with severe VHD is a clinical condition with a very high risk of mortality for which surgical treatment is often deemed a prohibitive risk. Transcatheter valve interventions might be a promising alternative in this setting given that they are less invasive. However, supportive scientific evidence is scarce and often limited to small case series. Current guidelines on VHD do not contain specific recommendations on how to manage patients with both VHD and CS. The purpose of this clinical consensus statement, developed by a group of international experts invited by the European Association of Percutaneous Cardiovascular Interventions (EAPCI) Scientific Documents and Initiatives Committee, is to perform a review of the available scientific evidence on the management of CS associated with left-sided VHD and to provide a rationale and practical approach for the application of transcatheter valve interventions in this specific clinical setting.

16.
Catheter Cardiovasc Interv ; 102(2): 318-327, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37354444

RESUMO

BACKGROUND: Transcatheter mitral valve implantation (TMVI) is a novel therapeutic option for treating symptomatic mitral valve disease. Evaluating patient anatomical suitability is a critical step in the TMVI screening process, but currently requires specialized software and computerized device models. AIMS: This analysis sought to assess the effectiveness of simple and standardized multislice computed tomography (MSCT) anatomic measurements for their ability to discriminate between patients who passed anatomical screening for Tendyne™ TMVI. METHODS: Subjects screened for the Tendyne Expanded Clinical Study from January 2016 through September 2019 were included. Core laboratory screening measurements included mitral annular (MA) dimensions at end-systole and end-diastole, simulated device implantation, and neo-left ventricular outflow tract (LVOT) area. Additionally, nine standard measurements of patient anatomy were assessed for their predictive value of patients passing the anatomic screening process. RESULTS: Out of 496 subjects screened for eligibility, 257 subjects met clinical eligibility criteria with MA dimensions within the manufacturer's suggested range: 153 (59.5%) underwent TMVI while 104 (40.5%) were excluded from the study for other anatomic reasons (76% due to risk of LVOT obstruction). CT-derived left ventricular end-systole diameter (LVESD) had the highest discriminatory power for predicting TMVI anatomical suitability (area under the curve of 0.908, p < 0.0001). The mitral inter-commissural (IC) dimension was best predictive of annular dimensions being within range, with dimensions <30 or >50 mm resulting in a negative predictive value of 94.4%. CONCLUSIONS: MSCT-derived mitral IC dimension and LVESD easily performed measures that are effective predictors of anatomical suitability or screen failure for this tether-based TMVI device.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco , Resultado do Tratamento
17.
EuroIntervention ; 19(6): 512-525, 2023 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-37235388

RESUMO

BACKGROUND: Transcatheter mitral valve replacement (TMVR) using dedicated devices is an alternative therapy for high-risk patients with symptomatic mitral regurgitation (MR). AIMS: This study aimed to assess the 2-year outcomes and predictors of mortality in patients undergoing TMVR from the multicentre CHOICE-MI Registry. METHODS: The CHOICE-MI Registry included consecutive patients with symptomatic MR treated with 11 different dedicated TMVR devices at 31 international centres. The investigated endpoints included mortality and heart failure hospitalisation rates, procedural complications, residual MR, and functional status. Multivariable Cox regression analysis was applied to identify independent predictors of 2-year mortality. RESULTS: A total of 400 patients, median age 76 years (interquartile range [IQR] 71, 81), 59.5% male, EuroSCORE II 6.2% (IQR 3.8, 12.0), underwent TMVR. Technical success was achieved in 95.2% of patients. MR reduction to ≤1+ was observed in 95.2% at discharge with durable results at 1 and 2 years. New York Heart Association Functional Class had improved significantly at 1 and 2 years. All-cause mortality was 9.2% at 30 days, 27.9% at 1 year and 38.1% at 2 years after TMVR. Chronic obstructive pulmonary disease, reduced glomerular filtration rate, and low serum albumin were independent predictors of 2-year mortality. Among the 30-day complications, left ventricular outflow tract obstruction, access site and bleeding complications showed the strongest impact on 2-year mortality. CONCLUSIONS: In this real-world registry of patients with symptomatic MR undergoing TMVR, treatment with TMVR was associated with a durable resolution of MR and significant functional improvement at 2 years. Two-year mortality was 38.1%. Optimised patient selection and improved access site management are mandatory to improve outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Masculino , Idoso , Feminino , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/métodos , Resultado do Tratamento , Fatores de Risco , Sistema de Registros
18.
Circ Cardiovasc Interv ; 16(6): e013045, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37194288

RESUMO

BACKGROUND: Transcatheter mitral valve replacement (TMVR) is an emerging therapeutic alternative for patients with secondary mitral regurgitation (MR). Outcomes of TMVR versus guideline-directed medical therapy (GDMT) have not been investigated for this population. This study aimed to compare clinical outcomes of patients with secondary MR undergoing TMVR versus GDMT alone. METHODS: The CHOICE-MI registry (Choice of Optimal Transcatheter Treatment for Mitral Insufficiency) included patients with MR undergoing TMVR using dedicated devices. Patients with MR pathogeneses other than secondary MR were excluded. Patients treated with GDMT alone were derived from the control arm of the COAPT trial (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation). We compared outcomes between the TMVR and GDMT groups, using propensity score matching to adjust for baseline differences. RESULTS: After propensity score matching, 97 patient pairs undergoing TMVR (72.9±8.7 years; 60.8% men; transapical access, 91.8%) versus GDMT (73.1±11.0 years; 59.8% men) were compared. At 1 and 2 years, residual MR was ≤1+ in all patients of the TMVR group compared with 6.9% and 7.7%, respectively, in those receiving GDMT alone (both P<0.001). The 2-year rate of heart failure hospitalization was significantly lower in the TMVR group (32.8% versus 54.4%; hazard ratio, 0.59 [95% CI, 0.35-0.99]; P=0.04). Among survivors, a higher proportion of patients were in the New York Heart Association functional class I or II in the TMVR group at 1 year (78.2% versus 59.7%; P=0.03) and at 2 years (77.8% versus 53.2%; P=0.09). Two-year mortality was similar in the 2 groups (TMVR versus GDMT, 36.8% versus 40.8%; hazard ratio, 1.01 [95% CI, 0.62-1.64]; P=0.98). CONCLUSIONS: In this observational comparison, over 2-year follow-up, TMVR using mostly transapical devices in patients with secondary MR was associated with significant reduction of MR, symptomatic improvement, less frequent hospitalizations for heart failure, and similar mortality compared with GDMT. REGISTRATION: URL: https://clinicaltrials.gov; Unique identifier: NCT04688190 (CHOICE-MI) and NCT01626079 (COAPT).


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Feminino , Humanos , Masculino , Cateterismo Cardíaco/efeitos adversos , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Pontuação de Propensão , Resultado do Tratamento
19.
EuroIntervention ; 19(6): 502-511, 2023 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-37203860

RESUMO

BACKGROUND: Prospective data about transcatheter aortic valve implantation (TAVI) in bicuspid aortic valve (BAV) patients are limited. AIMS: We aimed to evaluate the clinical impact of the Evolut PRO and R (34 mm) self-expanding prostheses in BAV patients and explore the impact of different computed tomography (CT) sizing algorithms in a prospective registry. METHODS: A total of 149 bicuspid patients were treated in 14 countries. The primary endpoint was the intended valve performance at 30 days. Secondary endpoints were 30-day and 1-year mortality, severe patient-prosthesis mismatch (PPM) and the ellipticity index at 30 days. All study endpoints were adjudicated according to Valve Academic Research Consortium 3 criteria. RESULTS: The mean Society of Thoracic Surgeons score was 2.6% (1.7-4.2). Type I L-R BAV was observed in 72.5% of the patients. Evolut valve sizes 29 and 34 mm were utilised in 49.0% and 36.9% of the cases, respectively. The 30-day cardiac death rate was 2.6%; the 1-year cardiac death rate was 11.0%. Valve performance at 30 days was observed in 142/149 (95.3%) patients. The mean aortic valve area post-TAVI was 2.1 (1.8-2.6) cm2, and the mean aortic gradient was 7.2 (5.4-9.5) mmHg. No patient had more than moderate aortic regurgitation at 30 days. PPM was observed in 13/143 (9.1%) surviving patients and was severe in 2 patients (1.6%). Valve function was maintained at 1 year. The mean ellipticity index remained 1.3 (interquartile range 1.2-1.4). Overall, 30-day and 1-year clinical and echocardiography outcomes were similar between the two sizing strategies. CONCLUSIONS: BIVOLUTX demonstrated a favourable bioprosthetic valve performance and good clinical outcomes after TAVI with the Evolut platform in patients with bicuspid aortic stenosis. No impact from the sizing methodology could be identified.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Estenose da Valva Mitral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Doença da Válvula Aórtica Bicúspide/etiologia , Doença da Válvula Aórtica Bicúspide/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Constrição Patológica , Resultado do Tratamento , Desenho de Prótese , Estudos Prospectivos , Doenças das Valvas Cardíacas/cirurgia , Estenose da Valva Mitral/cirurgia , Sistema de Registros , Morte
20.
Catheter Cardiovasc Interv ; 101(6): 1134-1143, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37036268

RESUMO

OBJECTIVE: To determine the prognostic impact of coronary artery disease (CAD) in patients randomized to bivalirudin or unfractionated heparin (UFH) during transcatheter aortic valve replacement (TAVR). BACKGROUND: CAD is a common comorbidity among patients undergoing TAVR and studies provide conflicting data on its prognostic impact. METHODS: The Bivalirudin on Aortic Valve Intervention Outcomes-3 (BRAVO-3) randomized trial compared the use of bivalirudin versus UFH in 802 high-surgical risk patients undergoing transfemoral TAVR for severe symptomatic aortic stenosis. Patients were stratified according to the presence or absence of history of CAD as well as periprocedural anticoagulation. The coprimary endpoints were net adverse cardiac events (NACE; a composite of all-cause mortality, myocardial infarction, stroke, or major bleeding) and major Bleeding Academic Research Consortium (BARC) bleeding ≥3b at 30 days postprocedure. RESULTS: Among 801 patients, 437 (54.6%) had history of CAD of whom 223 (51.0%) received bivalirudin. There were no significant differences in NACE (adjusted odds ratio [OR]: 1.04; 95% confidence interval [CI]: 0.69-1.58) or BARC ≥ 3b bleeding (adjusted OR: 0.84; 95% CI: 0.51-1.39) in patients with vs without CAD at 30 days. Among CAD patients, periprocedural use of bivalirudin was associated with similar NACE (OR: 0.80; 95% CI: 0.47-1.35) and BARC ≥ 3b bleeding (OR: 0.64; 95% CI: 0.33-1.25) compared with UFH, irrespective of history of CAD (p-interaction = 0.959 for NACE; p-interaction = 0.479 for major bleeding). CONCLUSION: CAD was not associated with a higher short-term risk of NACE or major bleeding after TAVR. Periprocedural anticoagulation with bivalirudin did not show any advantage over UFH in patients with and without CAD.


Assuntos
Doença da Artéria Coronariana , Substituição da Valva Aórtica Transcateter , Humanos , Heparina/efeitos adversos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Antitrombinas/efeitos adversos , Resultado do Tratamento , Hirudinas/efeitos adversos , Hemorragia/induzido quimicamente , Fragmentos de Peptídeos/efeitos adversos , Proteínas Recombinantes/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...